Compressor controller mam 860 mam 870 mam 880 mam 890 mam 6090

Compressor controller mam 860 mam 870 mam 880 mam 890 mam 6090

FOB Price

Get Latest Price

110 ~ 150 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

1 Piece

Packaging Detail:

cartoon

Delivery Time:

5 days

Supplying Ability:

1000 Piece per Week

Payment Type:

PayPal, Money Gram, Western Union, L/C, T/T

Contact Now
Free Member

Contact Person Mr. MUSTAFA

ikitelli, Istanbul, kucukcekmece

Contact Now

Description

Skype : mfbalmustafa - Mobile / Whatsapp / viber : +90 535 250 51 45 - *@********************ng>

 
Screw Comrpessor Controller ,


Features
 
  • English display. 
  • Remote control/Local control. 
  • Block mode/Independent mode. 
  • On-off control of motor. 
  • Prevention for air compressor reversion. 
  • Temperature measurement, control and protection. 
  • Voltage measurement and protection. 
  • RS485 communication function, supporting MODBUS RTU protocol. 
  • Protection for open phase, overload current, unbalance current, high voltage, low voltage. 
  • High integration, high reliability, high cost performance.
5, Control Process
  
 
1, Single Machine
 
1, working principle (On/off mode: Local; Load mode: Auto)
 
. Press image to start:    (Y-start)
imageThe air compressor can not be started by pressing          until 5 seconds self checking finished. The
 
start process of compressor is as followed: 18 terminal closed, KM2 is energized;17 terminal closed ,KM3 is energized → Y start → STAR DELAY time starts record; when Y-transfer time over,17 terminal open ,KM3 is de-energized and 16 terminal closed,KM1 is energized → motor operates in. (KM1 and KM3 are interlocked)
 
. Automatic operation control:
 
A, When motor enter delta status, LOAD DELAY starts, controller will load automatically after
 
LOAD DELAY.
 
B, If air pressure is detected higher than UNLOADING P set,15 terminal opens, loading valve is de-energized, and air compressor starts unloading, and also starts EMPTY LONG STOP time record ,if unloading time exceed EMPTY LONG STOP set, compressor will enter STANDBY mode; if compressor loading again within EMPTY TIME set(when pressure is below LOADING P or receiving load command),compressor will reset EMPTY LONG STOP.
C, In STANDBY mode, controller start automatically if pressure detected is below LOADING P
 
. Manual loading/unloading operation under automatic status
 
A: When air pressure is between LOADING P and UNLOADING P, press loading/ unloading to switch the current status of controller.
B, When air pressure is above the UNLOADING P, controller unloads automatically, the loading/unloading button is invalid
C, When air pressure is below the UNLOADING P, controller loads automatically, the loading/unloading button is invalid
. Normal stop:
 
Press image  , the loading magnetic valve will be de-energized, after a while of delay (stop delay), all output relay stop working.
 
. The frequent starting control
 
Air compressor can not start again immediately after NORMAL STOP ,EMPTY LONG STOP or FAILURE STOP. It can start again after START DELAY.
 
2, Remote Automatic Control (Control Mode: Remote; Load Mode: Auto)
 
In this mode, compressor can be turned on or off by remote control .
 
1, Local Control (Control Mode: local, Load Mode: Manual)
 
A, Control of start and stop are same as automatic control, but device is in status of unloading after finish
 
starting process.
 
B, In unload status, press image  to load . When air pressure is higher than UNLOADING P set, the device will unload automatically.
 
C, If not press loading/ unloading, the device will run unload until EMPTY LONG STOP.
D, In load status, press image  to unload.
-17 -

2, Net Work
 
.Controller works as slave when communication mode is set as computer, and communicates with monitoring center through MODBUS.
 
.Controller and other controller can block work when communication mode is set block but the master only can service as 1# compressor.
 
3, Fan Operation
 
When discharge air temperature is higher than FAN START T, fan operates; when discharge air temperature is lower than FAN STOP T, fan stops.
 

Skype : mfbalmustafa - Mobile / Whatsapp / viber : +90 535 250 51 45 - mustafa